Recalls & Field Safety Notices
As a service to our customers Regional Home Care presents the following recalls and field safety notices for review. For additional information please contact the manufacturer's in question.
September 8, 2026
BMC Medical Co., Ltd. Recalls Luna G3 APAP (Model LG3600) With Firmware G3-2.00.76 Due To Firmware Defect
On July 15, 2026, BMC Medical Co., Ltd. (BMC), Beijing, China, retrospectively reported to the US Food and Drug Administration (FDA) a recall of 20,160 Luna G3 APAP (Model LG3600) devices distributed in the United States due to firmware defect. This corrective action was not reported to customers. On August 19, 2026, the FDA classified this retrospective recall as a Class I recall (FDA Recall Number: Z-2979-2026). BMC has identified that firmware version, G3-2.00.76 installed on these Luna G3 APAP (Model LG3600) devices contained a firmware defect. BMC conducted a firmware upgrade of these devices to version G3-2.00.77 for 20,160 affected devices at the U.S. importer’s warehouse from October through December 2024. After reporting the retrospective recall, BMC discovered that potentially up to 196 units did not receive the upgrade and identified that these devices may still contain firmware version G3-2.00.76. If the affected device(s) operates simultaneously under high pressure, high respiratory rate, and high peak flow an "Error" message on the device display is triggered, followed by automatic shutdown resulting in a failure to deliver therapy. The firmware defects could result in unintended serious adverse health consequences. To date, BMC has received no complaints or serious adverse reports associated with this firmware failure.
- Visit the BMC Medical Luna G3 APAP Recall Notification Page
- Visit the FDA's BMC Medical Luna G3 APAP Recall Company Announcement Page
- Direct Questions About this Recall to bmc-recall@bmc-medical.com or call 863-226-6285
18 September 2025
Fisher & Paykel Urgent: Medical Device Correction (Fisher & Paykel Healthcare Airvo 2 and myAirvo 2 Disinfection Kit User Manual Update related to audible alert sounding for less than 120 seconds when unintentionally disconnected from a power source)
Fisher & Paykel Healthcare (F&P) is initiating a Medical Device Correction to inform you of an update to the Disinfection Kit User Manual for Airvo 2 and myAirvo 2 devices. This update has been made due to reports of the audible alert sounding for less than 120 seconds when the unit is unintentionally disconnected from a power source. This may delay user awareness to reconnect power. A delay in reconnecting power could lead to a patient experiencing oxygen desaturation that may lead to hypoxia.
- Visit the F&P Airvo 2 & MyAirvo 2 Urgent Medical Device Correction Website
- Read Fisher & Paykel's Urgent Medical Device Correction Notification
- Direct Questions About this Urgent Medical Device Correction to FieldActionUSCA@fphcare.com or call 800-446-3908 ext 5003 or 949-453-4000
1 March 2024
Sleepnet Medical Device Recall (Sleepnet Masks with Magnets including Mojo, Mojo 2, IQ 2, Phantom 2, etc.)
Sleepnet Corporation is voluntarily recalling masks with magnets which are intended to be used with positive airway pressure devices such as CPAP or bi-level. Masks included in the recall are the Mojo Full Face Vented Mask, Mojo Full Face Non Vented Mask, Mojo 2 Full Face Vented Mask, Mojo 2 Full Face Non Vented Mask, Mojo 2 Full Face AAV Non Vented Mask, iQ 2 Nasal Mask, and the Phantom 2 Nasal Mask.This recall is being initiated based on information obtained from post market surveillance indicating a possible risk to patients and anyone in close physical contact with the mask, having an active medical implant or metallic implant that can be impacted by the magnetic field. The existing contraindications and warnings are being revised as a proactive measure to provide additional safety information to patients and healthcare professionals. To date, there have been no Medical Device Reports associated with the Sleepnet masks with magnets. To learn more about the recall and what steps you should take please click the link below.
- Read SleepNet's Urgent Medical Device Recall Announcement
- Direct Questions About this Recall to Sleepnet at 1-800-742-3646 or visit them online
20 November 2023
Resmed Urgen Field Safety Notice (Resmed Masks with Magnets - Potential Magnetic Interference with Certain Medical Devices)
ResMed is providing patients with important information regarding their masks with magnets, which may interact with some implants or certain medical devices. In response to new information from latest industry practices and global safety data, ResMed is updating the Contraindications and Warnings in their User Guides to instruct patients on the safe use of ResMed masks with magnets. Affected masks include: AirFit F20, AirFit F20 for Her, AirTouch F20, AirTouch F20 for Her, AirFit F30, AirFit F30i, AirFit N10, AirFit N10 for Her, AirFit N20, AirFit N20 for Her, AirTouch N20, AirTouch N20 for Her, AirFit F20 NV.
- Read ResMed's Updated Information on Masks with Magnets for Mask Users Online
- Download a Copy of ResMed's Urgent Field Safety Notice (Masks with Magnets)
- Direct Questions About this Correction to ResMed using details in the documents above
16 November 2023
SoClean Urgent Medical Device Field Correction (SoClean 2 and SoClean 3 Automated Supplemental Sleep Equipment Maintenance Systems)
SoClean is conducting a voluntary field action intended to update and clarify the user manuals for all units of the SoClean2 and SoClean3. This voluntary field correction does not require you to stop using or return your SoClean unit. SoClean is revising its labeling to incorporate: (i) additional warnings and contraindications; and (ii) proper and consistent device set-up instructions including use of a hose and mask adapter, thereby reducing potential risks associated with the previous device design and labeling.
- Read SoClean's Urgent Medical Device Field Correction Online
- Download a Copy of SoClean's Urgent Medical Device Field Correction
- Direct Recall Questions to SoClean at 866-501-3705
September 2022
Philips Urgent Medical Device Correction (Masks with Magnets)
Philips Respironics is alerting users of certain CPAP or Bi-Level PAP therapy masks with magnetic headgear clips or straps that these devices should not be used by or near patients and their household members, caregivers and bed partners who have metallic implanted devices or metallic objects (such as metallic splinters) in the body. The magnetic headgear clips are used to attach the headgear straps to the masks, which is a method that is commonly used in the sleep therapy devices industry. These masks may continue to be used according to the updated instructions and labeling if patients or people in close proximity to them do not have implanted metallic medical devices or metallic objects in the body. To learn more about this Urgent Medical Device Correction use the links below.
- Read the Full Urgent Medical Device Correction Notice Online
- Download a Copy of Philips Urgent Medical Device Correction
- Download Philips Urgent Medical Device Correction FAQ
- Direct Questions About this Correction to Philips at 877-387-3311
June 2021
Philips Voluntary Recall Information (Various Devices Including DreamStation)
After discovering a potential health risk related to the foam in certain CPAP, BiPAP and Mechanical Ventilator devices, Philips Respironics issued a voluntary Field Safety Notice (outside U.S.) / voluntary recall notification (U.S. only) for various Continuous and Non-Continuous Ventilators (certain CPAP, BiLevel PAP and Ventilator) devices. For information on the recall, the registration process, a complete list of impacted products, and potential health risks, use the links below:
- Philips Respironics Sleep & Respiratory Care Devices Voluntary Recall Information
- Direct Recall Questions to Philips at 877-907-7508
- Click Here to Register Your Device for Recall Service